Strep-Tactin Magnetic Beads
  • Home
  • Hot Products
  • Magnetic Beads
  • Strep-Tactin Magnetic Beads
  • Strep-Tactin Magnetic Beads

    Product Introduction:
    Strep-Tactin is a genetically engineered variant of streptavidin that can be used for surface coating. Strep-tag II is an 8-residue minimal peptide sequence (Trp-Ser-His-Pro-Gln-Phe-Glu-Lys) with intrinsic affinity for streptavidin. Research has found that Strep-tag II can bind with high selectivity to Strep-Tactin.

    Strep-Tactin magnetic beads are commonly used in protein purification applications. They can effectively isolate and purify Strep-tag II proteins from a complex biological mixture.

    Our Products

    Alfa Chemistry utilizes a special protein conjugation process to covalently couple Strep-Tactin to the surface of superparamagnetic magnetic beads, creating a new type of magnetic bead capable of efficiently and rapidly separating and purifying Strep-tag II proteins. Our Strep-Tactin magnetic beads can be used to isolate and purify functional Strep-tag II proteins from any expression system, including baculovirus, yeast, mammalian cells and bacteria.

    Product NameStrep-Tactin Magnetic Beads
    Catalog NumberNM-MBs068
    Bead Size30-150 μm
    Bead LigandStrep-Tactin
    Ligand Content~6 mg Strep-Tactin/1 mL gel
    Protein Binding Capacity~7 mg Strep-tag II protein/1 mL gel
    Suspension Concentration10% (V/V) Magnetic beads suspension
    Preservation Solution1×PBS (0.1% Tween 20+0.1% Proclin 300)
    Binding/Washing Buffer10 mM Tris-HCl, 150 mM NaCl, 1 mM EDTA, pH 8.0
    Elution Buffer2.5 mM Desthiobiotin in binding buffer
    Regeneration Buffer0.5 M NaOH or 1 mM HABA in binding buffer
    Storage ConditionSeal and store at 4 °C for 24 months. Do not freeze. Mix well before use.

    *The amount of protein binding is related to the characteristics of the target protein, and only the reference value is given here.
    **If you have a need for other specifications, we can also provide you with product customization.

    Optimization of Protein Purification Process

    Methods to improve the recovery of target proteins:
    (a) Extend the incubation time of the protein solution with the magnetic beads.
    (b) Include appropriate protease inhibitors to prevent degradation of the target protein.
    (c) Increase the amount of magnetic beads used.
    (d) Extend the elution time of the target protein or increase the number of elutions.

    Methods to improve the purity of the target protein:
    (a) Include appropriate protease inhibitors during purification to prevent degradation of the target protein.
    (b) Extend the washing time and increase the number of washes.

    You Need to Know

    • Do not freeze, dry, or d high-speed centrifuge our products.
    • Before using our products, make sure to thoroughly oscillate to maintain a uniform suspension of the beads.
    • It is recommended to use high-quality pipette tips and reaction tubes to prevent the magnetic beads from sticking to the walls or leakage during the mixing process, which can cause loss of magnetic beads.
    • When the used magnetic beads are reused, it is recommended to purify the same kind of proteins. When purifying different proteins, it is recommended to use new magnetic beads to avoid cross-contamination.
    • Our products need to be used with magnetic separation equipment.
    • Our products are for research use only.

    Related Products